產(chǎn)品安全認(rèn)證
危險(xiǎn)環(huán)境產(chǎn)品認(rèn)證
危險(xiǎn)場(chǎng)所使用的產(chǎn)品的認(rèn)證
美國(guó),加拿大,歐洲ATEX指令
- MET擁有超過(guò)30年在危險(xiǎn)(分級(jí))場(chǎng)所使用的產(chǎn)品認(rèn)證經(jīng)驗(yàn)。
- MET實(shí)驗(yàn)室是世界首家獲得美國(guó)職業(yè)安全與衛(wèi)生管理局(OSHA)認(rèn)可的國(guó)家認(rèn)可實(shí)驗(yàn)室(NRTL),對(duì)在美國(guó)市場(chǎng)銷售的產(chǎn)品進(jìn)行認(rèn)證。
- MET實(shí)驗(yàn)室獲得加拿大標(biāo)準(zhǔn)理事會(huì)(SCC)認(rèn)可,對(duì)在加拿大市場(chǎng)銷售的產(chǎn)品進(jìn)行認(rèn)證。
- MET,與公告機(jī)構(gòu)合作,能夠在ATEX指令下作產(chǎn)品認(rèn)證. http://europa.eu.int/comm/enterprise/atex/guide/
- MET能夠根據(jù)你的需要提供技術(shù)輔導(dǎo)。
MET能夠提供以下標(biāo)準(zhǔn)的認(rèn)證
美國(guó)
- UL913 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division I, Hazardous (Classified) Locations
- UL1604 Electrical Equipment for Use in Class I and II, Division 2, and Class III Hazardous (Classified) Locations
- UL1203 Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations-Third Edition
- NFPA 496 Purged and Pressurized Enclosures for Electrical Equipment
- FM3600 Electrical Equipment for Use in Hazardous (Classified) Locations, General Requirements
- FM3610 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II and III, Division 1 Hazardous (Classified) Locations
- FM3611 Electrical Equipment for Use in Class I, Division 2; Class II, Division 2; and Class III, Division 1 and 2 Hazardous Locations
- FM3615 Explosion proof Electrical Equipment, General Requirements
- FM3620 Purged and Pressurized Electrical Equipment for Hazardous (Classified) Locations
- UL60079-0 Electrical Apparatus for Explosive Gas Atmospheres Part 0: General Requirements
- UL60079-1 Electrical Apparatus for Explosive Gas Atmospheres Part 1: Flameproof Enclosures "d"
- UL60079-7 Electrical Apparatus for Explosive Gas Atmospheres Part 7: Increased Safety "e"-First Edition
- UL60079-11 Electrical Apparatus for Explosive Gas Atmospheres Part 11: Intrinsic Safety "i"
- UL60079-15 Electrical Apparatus for Explosive Gas Atmospheres Part 15: Electrical Apparatus with Type of Protection "n"
加拿大
- CSA C22.2 No 157 Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations; Consumer and Commercial Products
- CSA C22.2 No 213 Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations Industrial Products
- CSA C22.2 No 25 Enclosures for Use in Class II Groups E, F, and G Hazardous Locations
- CSA C22.2 No 30 Explosion-Proof Enclosures for Use in Class I Hazardous Locations Industrial Products
- CSA E60079-0 Electrical Apparatus for Explosive Gas Atmospheres Part 0: General Requirements
- CSA E60079-1 Electrical Apparatus for Explosive Gas Atmospheres Part 1: Flameproof Enclosures "d"
- CSA E60079-2 Electrical Apparatus for Explosive Gas Atmospheres Part 2: Pressurized Enclosures "p"-Second Edition
- CSA E60079-7 Electrical Apparatus for Explosive Gas Atmospheres Part 7: Increased Safety "e"-First Edition
- CSA E60079-11 Electrical Apparatus for Explosive Gas Atmospheres Part 11: Intrinsic Safety "i"
- CSA E60079-15 Electrical Apparatus for Explosive Gas Atmospheres Part 15: Electrical Apparatus with Type of Protection "n"
歐盟:
- EN 60079-0 Electrical Apparatus for Explosive Gas Atmospheres Part 0: General Requirements
- EN 60079-1 Electrical Apparatus for Explosive Gas Atmospheres Part 1: Flameproof Enclosures "d"
- EN 60079-2 Electrical Apparatus for Explosive Gas Atmospheres Part 2: Pressurized Enclosures "p"-Second Edition
- EN 60079-7 Electrical Apparatus for Explosive Gas Atmospheres Part 7: Increased Safety "e"-First Edition
- EN 60079-11 Electrical Apparatus for Explosive Gas Atmospheres Part 11: Intrinsic Safety "i"
- EN 60079-15 Electrical Apparatus for Explosive Gas Atmospheres Part 15: Electrical Apparatus with Type of Protection "n"